AC Capacitors in Bahrain

An AC run capacitor gives the compressor and fan motors the phase shift they need to run smoothly. Its microfarad (µF) rating and voltage must match the original, because a wrong value can overheat the motor or compressor. A capacitor that is swollen, leaking or burnt, or a unit that hums but does not start, usually points to a failed capacitor.

Always switch off the power and discharge a capacitor before touching it. A dual capacitor lists two µF values, for example 35+5 µF, one for the compressor and one for the fan, so use the same pairing as the old one.

The dual run capacitors we list are SAMREF CBB65 types rated 440VAC (also suitable where 370V is specified), each with its µF pairing in the product name. Look at the terminal markings on the old capacitor, usually Herm for the compressor and Fan for the fan motor, before you fit the new one so the connections go back exactly as they were.

Our catalogue currently lists 7 AC run capacitors from SAMREF. Each product has its own page with the model number and the specifications we hold for it. Stock changes, so message us the product code on WhatsApp to confirm availability and price.

AC run capacitors (7)

AC Run Capacitor (CBB65 35+5µF)
CW-CAP-102 · Capacitors

AC Run Capacitor (CBB65 35+5µF)

SAMREF Premium+ CBB65 heavy-duty dual run capacitor, 35+5µF ±5%, 440VAC (also suitable for 370V), 50/60Hz, -25°C to +85°C. Non-PCB dry type with MPP self-healing, burst-proof construction and a pressure-sensitive interrupter rated to safely interrupt up to 10,000 A of short-circuit current (10,000 AFC, available fault current). For AC compressors and motors.

Enquire Now
AC Run Capacitor (CBB65 45+5µF)
CW-CAP-103 · Capacitors

AC Run Capacitor (CBB65 45+5µF)

SAMREF Premium+ CBB65 heavy-duty dual run capacitor, 45+5µF ±5%, 440VAC (also suitable for 370V), 50/60Hz, -25°C to +85°C. Non-PCB dry type with MPP self-healing, burst-proof construction and a pressure-sensitive interrupter rated to safely interrupt up to 10,000 A of short-circuit current (10,000 AFC, available fault current). For AC compressors and motors.

Enquire Now
AC Run Capacitor (CBB65 50+5µF)
CW-CAP-104 · Capacitors

AC Run Capacitor (CBB65 50+5µF)

SAMREF Premium+ CBB65 heavy-duty dual run capacitor, 50+5µF ±5%, 440VAC (also suitable for 370V), 50/60Hz, -25°C to +85°C. Non-PCB dry type with MPP self-healing, burst-proof construction and a pressure-sensitive interrupter rated to safely interrupt up to 10,000 A of short-circuit current (10,000 AFC, available fault current). For AC compressors and motors.

Enquire Now
AC Run Capacitor (CBB65 55+5µF)
CW-CAP-105 · Capacitors

AC Run Capacitor (CBB65 55+5µF)

SAMREF Premium+ CBB65 heavy-duty dual run capacitor, 55+5µF ±5%, 440VAC (also suitable for 370V), 50/60Hz, -25°C to +85°C. Non-PCB dry type with MPP self-healing, burst-proof construction and a pressure-sensitive interrupter rated to safely interrupt up to 10,000 A of short-circuit current (10,000 AFC, available fault current). For AC compressors and motors.

Enquire Now
AC Run Capacitor (CBB65 60+5µF)
CW-CAP-106 · Capacitors

AC Run Capacitor (CBB65 60+5µF)

SAMREF Premium+ CBB65 heavy-duty dual run capacitor, 60+5µF ±5%, 440VAC (also suitable for 370V), 50/60Hz, -25°C to +85°C. Non-PCB dry type with MPP self-healing, burst-proof construction and a pressure-sensitive interrupter rated to safely interrupt up to 10,000 A of short-circuit current (10,000 AFC, available fault current). For AC compressors and motors.

Enquire Now
AC Run Capacitor (CBB65 65+5µF)
CW-CAP-107 · Capacitors

AC Run Capacitor (CBB65 65+5µF)

SAMREF Premium+ CBB65 heavy-duty dual run capacitor, 65+5µF ±5%, 440VAC (also suitable for 370V), 50/60Hz, -25°C to +85°C. Non-PCB dry type with MPP self-healing, burst-proof construction and a pressure-sensitive interrupter. For AC compressors and motors.

Enquire Now

Frequently asked questions

How do I choose the right AC capacitor?

Use the µF rating and voltage printed on the old capacitor. If it is a dual capacitor, match both values, such as 35+5 µF.

Can I use a capacitor with a different µF rating?

Use the rating printed on the original. A different value can overheat the motor or compressor and shorten its life.

How can I tell the capacitor has failed?

A swollen, leaking or burnt case is a clear sign, and so is a compressor or fan motor that hums but does not start. Switch off the power and discharge the capacitor before you check it.

Where can I buy AC capacitors in Bahrain?

Coolway has two branches: East Riffa (Shop 1641, Road 539, Block 905) and Tubli (Shop 187, Road 7, Block 713), both open 8:00 AM – 7:00 PM, Saturday to Thursday. Message us the product code on WhatsApp to confirm availability before you visit.

كباسيتر المكيفات في البحرين

نوفر كباسيتر (مكثفات) تشغيل للمكيفات من SAMREF، منها CBB65 المزدوج بجهد 440 فولت (ويصلح أيضاً لجهد 370 فولت). يجب أن تطابق السعة (µF) والجهد المكتوبين على الكباسيتر القديم، ويتكوّن الكباسيتر المزدوج من قيمتين مثل 35+5 µF، واحدة للكمبروسر والأخرى للمروحة. افصل الكهرباء وفرّغ الكباسيتر قبل لمسه.

Visit or message us

Coolway Refrigeration Spare Parts Co. W.L.L. stocks AC, refrigeration and washing machine spare parts at two branches in Bahrain, both open 8:00 AM – 7:00 PM, Saturday to Thursday.

More parts

Related reading

Browse the full catalogue